F350 and FFS30
Evaluation Unit F350 and Flame Sensor FFS30
Your advantages at a glance:
- Configurable with external user interface FB30
- 3 preselectable operating modes
- Available as single sensor or dual sensor (UV/IR)
- Protection class IP66/67
- Self-learning function flame ON/OFF
- Operation either via graphical user interface with status display or F300K remote software, mandatory for version without integrated user interface
- Fail-safe iFSB (internal LAMTEC Failsafe System Bus) between FFS30 and F350
- SIL 3 according to DIN EN 61508 Part 1-7
- Flame sensor available for Ex Zone 1
The flame monitoring system FFS30/F350 is mainly used in
- Complex combustion systems
- Retrofit
- Combustion plants with and without selection tasks
- Single and multi-fuel burners
- Combustion chamber monitoring
- Power plants, heating plants, process furnaces, waste incineration plants
- Combustion plants with restricted view of the flame
Features:
3 in 1: Three flame scanners in one.
Versatile, promising and highly intelligent
The FFS30 flame scanner offers digital flame analysis in both the UV and IR spectral ranges, making it suitable for virtually all combustion applications.
- Configurable with external user interface FB30
- Operation with Remote Software
- Ex zone 1
- SIL 3
Each model has a semiconductor sensor with two processors that allow continuous operation.
The FFS30 is a compact flame scanner with amplifier and relay units.
The FFS30K UV/IR model has two UV and IR sensors, making it one of the most versatile flame scanners on the market.
It is suitable for demanding applications such as multi-burner installations with different fuels or excessive background radiation.
Three channels allow the application of specific detection parameters for different fuels and operating situations - so the FFS30 combines three flame scanners in one.
Up to 32 FFS30 scanners can be linked and connected to a PC to perform real-time flame analysis and record trends.
| Technical Data | |
| Approvals |
EC Type Examination Certificate according to 2014/68/EU (Pressure Equipment Directive)
EC Type Examination Certificate according to 2016/426/EU (Gas Appliances Regulation)
SIL 3
CE Declaration of Conformity
USA and Canada
EX certificate FFS30
|
| Non Compact | |||
| FFS07 | FFS08 | FFS30 | |
| Power supply voltage | F152 + 24 VDC | F152 + 24 VDC | F350 + 24 VDC |
| Operating mode | Continuous operation | Continuous operation | Continuous operation |
| Degree of protection | IP66 for Ex zone 1 | X | IP66 |
| IP67 for Ex zone 2 | No Ex zone only as standard IP67 | IP67 | |
| Sensor type | UV, IR | UV, IR | UV, IR, UV/IR-1 Dual sensor |
| UV-1, UV-4, IR-1, IR-1 T | UV-1, UV-4, IR-1, IR-1 T, IR-1 T/S2 | UV-4, UV/IR-1, IR-2, IR-4 | |
| Operating temperature | -20 °C ... +65 °C (UV) | -20 °C ... +65 °C | -40 °C ... +85 °C |
| Operating temperature | -20 °C ... +60 °C (IR) | -20 °C ... +60 °C | |
| Ex zone 1 | II 2G Ex d IIC T6 Gb | II 2G Ex d IIC T6 Gb | |
| II 2D Ex tb IIIC T80 °C Db | X | II 2D Ex tb IIIC T80 °C Db | |
| Ex zone 2 | II 3G Ex nA IIC T5 (T6) Ge X | X | X |
| II 3D Ex tc IIIC T95 °C Dc X | X | X | |
| Display | X | X | Has to be connected with FB 30 |
| UL resp. Class 1 Div. 2 certified | UL 372 - UL listed | UL 372 - UL listed | UL / Cl 1 Div. 2 |
| Operation with Remote Software | X | X | Yes |
| Evaluation device | F152 | F152 | F350 |
| Safety Integrity Level (SIL) | F152 SIL 3 | F152 SIL 3 | F350 SIL 3 |
| Compact | ||
| F200K | F300K | |
| Power supply voltage | 24 VDC | 24 VDC |
| Operating mode | Continuous operation | Continuous operation |
| Degree of protection Ex zone 1 | IP66 | X |
| Degree of protection Ex zone 2 | IP66/67 | IP66/67 |
| Sensor type | UV, IR | UV, IR, UV/IR-1 dual sensor |
| UV-2, (Ex zone 1, Ex zone 2), UV-6 FO (Ex zone 2), IR-1 (Ex zone 1, Ex zone 2), IR-2 (no Ex zone) | UV-4, UV-4.6, UV-4.6 FO, UV/IR-1, IR-4, UV/IR-1 FO (as standard all in Ex zone 2) | |
| Operating temperature Ex zone 2 | -40 °C ... +75 °C (UV-2, UV-6 FO) | -40 °C ... +85 °C |
| -40 °C ... +60 °C (IR-1) | ||
| Operating temperature Ex zone 1 | -40 °C ... +65 °C (UV-2) | X |
| -40 °C ... +60 °C (IR-1) | ||
| Ex zone 1 | Ex II 2G, zone 1 // Ex II 2D- zone 21 | X |
| Ex db lic. T6 ... T5 Gb // Ex tb IIIC T80 °C, T95 °C Db | ||
| Ex zone 2 | Ex II 3G, zone 2 // Ex II 3D zone 22 | Ex nA nC ic IIC T5 (T6) Gc X |
| Ex nA nC IIC T6 ... T5 Gc X // Ex tc IIIC T85 °C Dc X | ||
| UL resp. Class 1 Div. 2 certified | UL certified/ Cl 1 Div.2 | UL certified/ UL + Cl 1 Div. 2 |
| Operation with Remote Software | X | Yes |
| Evaluation device | Compact | Compact |
| Safety Integrity Level (SIL) | SIL 3 | SIL 3 |
| Flame Scanner Remote Software (FSB) for F350 | ![]() |
| External User Interface FB30 | ![]() |
| Connection cable | ![]() |
| Brackets with screw connection | ![]() |
| Cooling air housing | ![]() |
| Power supplies | ![]() |
| Junction box | ![]() |
| Flame Scanner Testing Device FFP30 | ![]() |
You can find additional accessories in the
product catalogue.
Accessories available via our sales representatives
Further downloads can be found in the support section.
Deutsch
English
Francais